CG2030 Series Short and Grounded Fault Indicator
Detail

1. Key models

CG2030B, CG2032B, CG2034C, CG2035, etc.


2. Product overview

The CG2035 series product short and grounded fault indicator is an intelligent power fault monitoring device designed specifically for urban and rural power grid ring distribution systems. It can quickly identify short and grounded faults and accurately locate them, greatly reducing troubleshooting time and ensuring safe and stable operation of the power grid.


3. Functions & features

· Fault and temperature detection and indication

It adopts advanced detection algorithms and sensor technology to ensure the accuracy and real-time detection of faults and temperatures. Once a malfunction occurs or the temperature exceeds the set threshold, an alarm will be triggered to assist the staff in quickly locating the fault point.

· Automatic reset

After troubleshooting, the indicator can automatically reset within the set time or reset through remote control, reducing manual intervention.

· Remote communication

Some models have communication function with a RS485 interface, which can be connected to DTU for remote data transmission, and implement the standard State Grid IEC60870-5-101 protocol.

· Wide range adaptability

It’s suitable for different voltage classes and line types, with strong environmental adaptability.

· Easy installation and maintenance

Compact design, easy installation, suitable for live installation and removal, easy maintenance, and intelligent analysis.


4. Technical specifications

1. Short-circuit action current: Optional from 150A to 2,000A (accuracy ± 10%) to be determined by the user at the time of ordering

2. Grounding current: Optional from 10 A to 200A (accuracy ± 10%) to be determined by the user at the time of ordering

3. Measurement range of phase line temperature and ambient temperature:- 25℃ to 125℃(±1.5%fs )

4. Working environment:- 20 to 70℃   ≤95%RH

5. Working power supply: DC24V or DC48V (other power supply methods to be determined by the user at the time of ordering)

6. Short delay adjustment: Optional from 50ms to 800ms (default 50ms) to be determined by the user at the time of ordering

7. Automatic reset time: Optional from 1 to 24h to be determined by the user at the time of ordering

8. Remote signal contact capacity: AC220/1A

9. Indicator dimensions: 96 width x 48 height x 85 depth (mm); Indicator opening size: 93 × 44 (mm)


5. Applications

Distribution network lines: Real time monitoring of branch line faults

Ring main unit/switchgear: Quick location of the fault zone

New energy station: Protection of photovoltaic/wind power collection lines

Industrial and mining enterprises: Preventive maintenance to reduce power outage losses